    A new reliable device to assess trunk extensors strength
    (Acta of Bioengineering and Biomechanics, 2021) ; ;
    Reyes-Ferrada, Waleska
    ;
    Chirosa-Ríos, Luis
    ;
    Chirosa-Ríos, Ignacio
    ;
    Martínez-García, Darío
    ;
    Jerez-Mayorga, Daniel
    ;
    Rodríguez-Perea, Ángela
    Purpose: This study aimed to examine the reliability of trunk extensor strength assessment with a functional electromechanical dynamometer (FEMD). Methods: Thirty-one men performed strength assessment at different velocities (V) (V1 = 0.15 m·s−1, V2 = 0.30 m·s−1, V3 = 0.45 m·s−1) and range of movement (R) (R1 = 25% cm; R2 = 50% cm), and isometric contraction at 90º. Reliability was obtained through the intraclass correlation coefficient (ICC), typical error (TE), and coefficient of variation (CV). Results: The absolute reliability provided stable repeatability of the average eccentric strength in the V1R1 condition (CV = 9.52%) and the maximum eccentric strength in V1R1 (CV = 9.63%) and V2R2 (CV = 9.66%). The relative reliability of the trunk extensor’s average strength was good (ICC = 0.77–0.83) for concentric and good (ICC = 0.78–0.85) and moderate (ICC = 0.67–0.74) for eccentric contraction. Also, good (ICC = 0.77–0.81) and moderate (ICC = 0.55–0.74) reliability of the maximum strength were obtained for concentric and eccentric contraction. The most reliable manifestation to evaluate the concentric (CV = 11.33%) and eccentric (CV = 9.52%) strength was the average strength in the V1R1 condition and the maximum strength (CV = 10.29%) to isometric assessment. The average concentric strength in the V2R2 condition (r = 0.69) and the maximum eccentric strength in the V1R1 condition (r = 0.65) were the best related to the maximum isometric strength. Conclusions: FEMD is a highly reliable device to evaluate trunk extensors strength.
  • Thumbnail Image
    Publication
    Reliability of a standing isokinetic shoulder rotators strength test using a functional electromechanical dynamometer: effects of velocity
    (PEERJ, 2020)
    Martinez Garcia, Dario
    ;
    Rodriguez Perea, Angela
    ;
    Barboza, Paola
    ;
    ;
    Jerez Mayorga, Daniel
    ;
    Chirosa, Ignacio
    ;
    Chirosa Ríos, Luis Javier
    Background. The evaluation of the force in internal rotation (IR) and external rotation (ER) of the shoulder is commonly used to diagnose possible pathologies or disorders in the glenohumeral joint and to assess patient’s status and progression over time. Currently, there is new technology of multiple joint isokinetic dynamometry that allows to evaluate the strength in the human being. The main purpose of this study was to determine the absolute and relative reliability of concentric and eccentric internal and external shoulder rotators with a functional electromechanical dynamometer (FEMD). Methods. Thirty-two male individuals (21.46 ± 2.1 years) were examined of concentric and eccentric strength of shoulder internal and external rotation with a FEMD at velocities of 0.3 m s−1 and 0.6 m s−1 . Relative reliability was determined by intraclass correlation coefficients (ICC). Absolute reliability was quantified by standard error of measurement (SEM) and coefficient of variation (CV). Systematic differences across velocities testing circumstances, were analyzed with dependent t tests or repeated measures analysis of variance in case of two or more than two conditions, respectively. Results. Reliability was high to excellent for IR and ER on concentric and eccentric strength measurements, regardless of velocity used (ICC: 0.81–0.98, CV: 5.12–8.27% SEM: 4.06–15.04N). Concentric outcomes were more reliable than eccentric due to the possible familiarization of the population with the different stimuli. Conclusion. All procedures examined showed high to excellent reliability for clinical use. However, a velocity of 0.60 m s−1 should be recommended for asymptomatic male patients because it demands less time for evaluation and patients find it more comfortable.